Miota/Multisplit

Compatible Indoor Units

Performa

Performa is the base indoor unit against which all technical parameters and performance indicators of the multi-split systems are defined.

performa-right 1

Performa is the standard indoor unit on which all technical parameters, values, and performance indicators of the multi-split systems are based. The listed capacities, energy efficiency ratings, and noise levels for each model are calculated specifically in relation to this unit type, making it the primary reference point for comparing and evaluating performance.

Superforma

Superforma is a floor-mounted air conditioner for multi-split systems, offering flexible installation and effective comfort throughout the year.

superforma-indoor-front 1

Superforma is a floor-mounted indoor unit combining high efficiency with flexible installation options. The ideal solution for spaces with limited wall mounting area or a specific interior layout, this floor-standing unit delivers even heating and cooling, comfort, and reliable operation across all seasons.

Arctic2R

A high-efficiency indoor unit that enhances the performance, economy, and comfort of any multi-split system.

Arctic2R is a premium indoor unit that boosts the efficiency and output of any multi-split system. With improved technical specifications, higher energy efficiency, and optimized comfort, choosing the ARCTIC2R guarantees better operation, lower energy consumption, and outstanding heating and cooling results.

Technical Specifications

RX2M50A

2 X RAW-PE35A

Cooling capacity range 5.00 (1.8-5.5) kW
Heating Capacity range 5.60 (1.5-6.3) kW
Nominal power consumption 1.25 / 1.40 kW
Energy Consumption – Cooling A+++ SEER 8.5
Energy Consumption – Heating A++ SCOP 4.6
Pdesign – Cooling Pdesign 5.0 kW при +35℃
Pdesign – Heating Pdesign 4.2 kW при -10℃
Annual energy consumption 206 / 1 278 kWh/a
Operating temperature range (outdoor) – cooling -20~50 ℃
Operating temperature range (outdoor) – heating -25~24 ℃
Number of indoor units for connection 2
Outdoor unit
Sound pressure level 53 dB(A)
Maximum airflow 2 200 m³/h
Compressor type Двойно роторен инвертор
Outdoor unit dimensions 800 x 280 x 553 mm
Outdoor unit weight 35 kg
Installation data
Power supply 1 / 220-240 / 50 Ph/V/Hz
Operating current 9.8 A
Wiring 3 x 2.5 / 4 x 1.0 N x mm²
Refrigerant type R32
Refrigerant charge 1050 g
Piping length 6.35 / 9.52 ⌀ mm
Max. pipe length with / without refrigerant recharge 50 / 20 m
Additional refrigerant charge per extra meter 15 g/m
Max. height difference (outdoor / indoor unit) 15 m

RX3M60A

3 X RAW-PE35A

Cooling capacity range 6.00 (2.0-7.5) kW
Heating Capacity range 6.80 (1.7-8.0) kW
Nominal power consumption 1.50 / 1.66 kW
Energy Consumption – Cooling A+++ SEER 8.5
Energy Consumption – Heating A++ SCOP 4.6
Pdesign – Cooling Pdesign 6.0 kW при +35℃
Pdesign – Heating Pdesign 4.6 kW при -10℃
Annual energy consumption 247 / 1 400 kWh/a
Operating temperature range (outdoor) – cooling -20~43 ℃
Operating temperature range (outdoor) – heating -30~24 ℃
Number of indoor units for connection 2-3
Outdoor unit
Sound pressure level 55 dB(A)
Maximum airflow 3 000 m³/h
Compressor type Двойно роторен инвертор
Outdoor unit dimensions 890 x 340 x 705 mm
Outdoor unit weight 43 kg
Installation data
Power supply 1Ph/220-240V/50Hz Ph/V/Hz
Operating current 12.27 A
Wiring 3 x 2.5 / 4 x 1.0 N x mm²
Refrigerant type R32
Refrigerant charge 1200 g
Piping length 6.35 / 9.52 ⌀ mm
Max. pipe length with / without refrigerant recharge 50 / 30 m
Additional refrigerant charge per extra meter 15 g/m
Max. height difference (outdoor / indoor unit) 15 m

RX3M75A

3 X RAW-PE35A

Cooling capacity range 7.50 (2.2~9.0) kW
Heating Capacity range 8.60 (2.0~10.0) kW
Nominal power consumption 1.88 / 2.21 kW
Energy Consumption – Cooling A+++ SEER 8.5
Energy Consumption – Heating A++ SCOP 4.6
Pdesign – Cooling Pdesign 7.5 kW при +35℃
Pdesign – Heating Pdesign 5.3 kW при -10℃
Annual energy consumption 309 / 1 613 kWh/a
Operating temperature range (outdoor) – cooling -20~43 ℃
Operating temperature range (outdoor) – heating -30~24 ℃
Number of indoor units for connection 2-3
Outdoor unit
Sound pressure level 60 dB(A)
Maximum airflow 3 000 m³/h
Compressor type Двойно роторен инвертор
Outdoor unit dimensions 890 x 340 x 705 mm
Outdoor unit weight 49 kg
Installation data
Power supply 1Ph/220-240V/50Hz Ph/V/Hz
Operating current 15.5 A
Wiring 3 x 2.5 / 4 x 1.0 N x mm²
Refrigerant type R32
Refrigerant charge 1 500 g
Piping length 6.35 / 9.52 ⌀ mm
Max. pipe length with / without refrigerant recharge 60 / 30 m
Additional refrigerant charge per extra meter 15 g/m
Max. height difference (outdoor / indoor unit) 15 m

RX4M80A

4 X RAW-PE35A

Cooling capacity range 8.00 (2.65-10.0) kW
Heating Capacity range 9.60 (2.4-11.0) kW
Nominal power consumption 2.00 / 2.53 kW
Energy Consumption – Cooling A+++ SEER 8.5
Energy Consumption – Heating A+ SCOP 4.0
Pdesign – Cooling Pdesign 8.0 kW при +35℃
Pdesign – Heating Pdesign 5.5 kW при -10℃
Annual energy consumption 329 / 1 674 kWh/a
Operating temperature range (outdoor) – cooling -20~43 ℃
Operating temperature range (outdoor) – heating -30~24 ℃
Number of indoor units for connection 2-3-4
Outdoor unit
Sound pressure level 60 dB(A)
Maximum airflow 3 000 m³/h
Compressor type Двойно роторен инвертор
Outdoor unit dimensions 890 x 340 x 705 mm
Outdoor unit weight 52 kg
Installation data
Power supply 1Ph/220-240V/50Hz Ph/V/Hz
Operating current 15.9 A
Wiring 3 x 2.5 / 4 x 1.0 N x mm²
Refrigerant type R32
Refrigerant charge 1 800 g
Piping length 6.35 / 9.52 ⌀ mm
Max. pipe length with / without refrigerant recharge 70 / 40 m
Additional refrigerant charge per extra meter 15 g/m
Max. height difference (outdoor / indoor unit) 15 m
support-icon